{"id":29397,"date":"2026-07-22T19:45:31","date_gmt":"2026-07-22T19:45:31","guid":{"rendered":"https:\/\/muzammilhd.com\/swas\/?post_type=product&#038;p=29397"},"modified":"2026-07-23T08:43:11","modified_gmt":"2026-07-23T08:43:11","slug":"ezc100f-fixed-mccb-3-pole-20-amps-10ka-415-vac","status":"publish","type":"product","link":"https:\/\/muzammilhd.com\/swas\/product\/ezc100f-fixed-mccb-3-pole-20-amps-10ka-415-vac\/","title":{"rendered":"EZC100F &#8211; Fixed MCCB, 3 Pole, 20 Amps, 10kA\/415 VAC"},"content":{"rendered":"<p><!-- Paste this entire block into a WordPress Custom HTML block. --><\/p>\n<p><span style=\"color: #808080;\"><strong>Series\u00a0 \u00a0 \u00a0 \u00a0 :\u00a0 \u00a0 \u00a0 EazyPact EZC<\/strong><\/span><br \/>\n<span style=\"color: #808080;\"><strong>Model\u00a0 \u00a0 \u00a0 \u00a0 :\u00a0 \u00a0 \u00a0 EZC100F<\/strong><\/span><br \/>\n<span style=\"color: #808080;\"><strong>Trip Unit\u00a0 :\u00a0 \u00a0 \u00a0 TM-D<\/strong><\/span><\/p>\n<p><span style=\"color: #999999;\">EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50\/60Hz. The operational voltage is 550VAC 50\/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 20A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications.<\/span><\/p>\n<p><span style=\"color: #808080;\"><strong>MOULDED CASE CIRCUIT BREAKERS\u00a0 (MCCB)<\/strong><\/span><br \/>\n<span style=\"color: #808080;\">WITH FIXED THERMAL &amp;\u00a0 MAGNETIC TRIPS<\/span><\/p>\n<table width=\"835\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"835\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">Poles\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">3P<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"835\">\n<tbody>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">Network type<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">DC<\/span><br \/>\n<span style=\"color: #999999;\">AC<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"color: #808080;\"><span style=\"color: #999999;\">Network frequency<\/span><\/td>\n<td style=\"color: #808080;\"><span style=\"color: #999999;\">50\/60 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">[In] rated current\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">20 at 40 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">[Ui] rated insulation voltage\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">690 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">[Uimp] rated impulse withstand voltage<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">6 kV conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">[Ue] rated operational voltage<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">\u00a0550 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">250 V DC conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">Breaking capacity<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">25 kA Icu at 110&#8230;130 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">25 kA Icu at 220&#8230;240 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">5 kA Icu at 125 V DC 1P conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">5 kA Icu at 250 V DC 2P conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">5 kA Icu at 550 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">10 kA Icu at 380 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">10 kA Icu at 400&#8230;415 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">7.5 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #999999;\">[Ics] rated service breaking capacity<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">12.5 kA at 110\/130 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">12.5 kA at 220\/230\/240 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">2.5 kA at 125 V DC conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">2.5 kA at 250 V DC conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">2.5 kA at 550 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">5 kA at 380 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">5 kA at 400\/415 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">3.75 kA at 440 V AC 50\/60 Hz conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #808080;\">Suitability for isolation<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Yes conforming to IEC 60947-2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #808080;\">Trip unit name<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">TM-D<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #808080;\">Trip unit technology<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Thermal-magnetic<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #808080;\">Trip unit rating<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">20 A at 50 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"330\"><span style=\"color: #808080;\">Protection type\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Short-circuit protection<\/span><br \/>\n<span style=\"color: #808080;\">Overload protection<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Pollution degree<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">3 conforming to IEC 60664-1<\/span><br \/>\n<span style=\"color: #808080;\">3 conforming to IEC 947-1<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Complementary<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Control type\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Toggle<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Mounting mode\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Fixed<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Mounting support<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Backplate<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Upside connection<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Front<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Downside connection<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Front<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Mechanical durability<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">13000 cycles<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Connection pitch\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">35 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Local signalling\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Positive contact indication<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Neutral protection setting\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Without protection<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Earth-leakage protection\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">Without<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Height\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">175 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Width<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">75 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #808080;\">Depth\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #808080;\">60 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><span style=\"color: #808080;\"><strong>Environment<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #999999;\">Standards\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">JIS C8201-2-2<\/span><br \/>\n<span style=\"color: #999999;\">EN\/IEC 60947-2<\/span><br \/>\n<span style=\"color: #999999;\">GB\/T 14048.2<\/span><br \/>\n<span style=\"color: #999999;\">EN\/IEC 60947-1<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #999999;\">IP degree of protection\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">IP20 conforming to IEC 60529<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #999999;\">IK degree of protection\u00a0<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">IK07 conforming to IEC 62262<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #999999;\">Ambient air temperature for operation<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">-25 ~ 70 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #999999;\">Ambient air temperature for storage<\/span><\/td>\n<td width=\"505\"><span style=\"color: #999999;\">-35 ~ 85 \u00b0C<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong>MOULDED CASE CIRCUIT BREAKERS<\/strong><br \/>\nWITH FIXED THERMAL &amp; MAGNETIC TRIPS<\/p>\n","protected":false},"featured_media":29398,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[130],"product_cat":[185,141],"product_tag":[],"class_list":["post-29397","product","type-product","status-publish","has-post-thumbnail","product_brand-schneider-electric","product_cat-fixed-trips","product_cat-mccb","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product\/29397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/comments?post=29397"}],"version-history":[{"count":18,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product\/29397\/revisions"}],"predecessor-version":[{"id":29422,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product\/29397\/revisions\/29422"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/media\/29398"}],"wp:attachment":[{"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/media?parent=29397"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product_brand?post=29397"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product_cat?post=29397"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/muzammilhd.com\/swas\/wp-json\/wp\/v2\/product_tag?post=29397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}