BW32AAG – Fixed MCCB, 3 Pole, 3 Amps, 1.5kA/415 VAC
₨ 42,000.00
MOULDED CASE CIRCUIT BREAKERSÂ (MCCB)
WITH FIXED THERMAL &Â MAGNETIC TRIPS
| Current | AC |
|---|---|
| Pole | 3P |
| Rated Current | 3 Amps |
| Breaking Capacity | 1.5 kA |
| Model | BW32 AAG |

Series      :   G-TWIN BW Series
Model      :      BW32-AAG
G‑TWIN BW32-AAG is a 3-pole, fixed molded-case circuit breaker (MCCB) designed for general low-voltage line protection in industrial control panels and distribution installations. It has a 32AF frame and a 3A fixed hydraulic-magnetic trip unit, providing overload and instantaneous short-circuit protection. Its rated operational voltage is 440 VAC, and its breaking capacity is Icu/Ics 1.5/1 kA at 415 VAC (also 400/440 VAC). At 230/240 VAC, Icu/Ics is 2.5/2 kA. The breaker has a rated insulation voltage of 500 VAC and an impulse-withstand voltage of 6 kV. The 3-pole version measures 75 mm × 100 mm × 60 mm (W × H × D). It conforms to IEC 60947-2, EN 60947-2 (CE), JIS C 8201-2-1, and GB 14048.2 (CCC).
MOULDED CASE CIRCUIT BREAKERSÂ (MCCB)
WITH FIXED THERMAL &Â MAGNETIC TRIPS
| Specification | |
| Poles | 3PÂ Â Not complete |
| Network type | DC AC |
| Network frequency | 50/60 Hz |
| [In] rated current | 100 A at 40 °C |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 |
| Mechanical durability | 13000 cycles |
| Electrical durability | 5000 cycles |
| Breaking capacity | 25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 100 A at 50 °C |
| Protection type | Short-circuit protection Overload protection |
| Pollution degree | 3 conforming to IEC 60664-1 3 conforming to IEC 947-1 |
| Complementary | |
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 35 mm |
| Local signalling | Positive contact indication |
| Neutral protection setting | Without protection |
| Earth-leakage protection | Without |
| Height | 130 mm |
| Width | 75 mm |
| Depth | 60 mm |
| Environment | |
| Standards | JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25 ~ 70 °C |
| Ambient air temperature for storage | -35 ~ 85 °C |

Series      :   G-TWIN BW Series
Model      :      BW32-AAG
G‑TWIN BW32-AAG is a 3-pole, fixed molded-case circuit breaker (MCCB) designed for general low-voltage line protection in industrial control panels and distribution installations. It has a 32AF frame and a 3A fixed hydraulic-magnetic trip unit, providing overload and instantaneous short-circuit protection. Its rated operational voltage is 440 VAC, and its breaking capacity is Icu/Ics 1.5/1 kA at 415 VAC (also 400/440 VAC). At 230/240 VAC, Icu/Ics is 2.5/2 kA. The breaker has a rated insulation voltage of 500 VAC and an impulse-withstand voltage of 6 kV. The 3-pole version measures 75 mm × 100 mm × 60 mm (W × H × D). It conforms to IEC 60947-2, EN 60947-2 (CE), JIS C 8201-2-1, and GB 14048.2 (CCC).
MOULDED CASE CIRCUIT BREAKERSÂ (MCCB)
WITH FIXED THERMAL &Â MAGNETIC TRIPS
| Specification | |
| Poles | 3PÂ Â Not complete |
| Network type | DC AC |
| Network frequency | 50/60 Hz |
| [In] rated current | 100 A at 40 °C |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 |
| Mechanical durability | 13000 cycles |
| Electrical durability | 5000 cycles |
| Breaking capacity | 25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 100 A at 50 °C |
| Protection type | Short-circuit protection Overload protection |
| Pollution degree | 3 conforming to IEC 60664-1 3 conforming to IEC 947-1 |
| Complementary | |
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 35 mm |
| Local signalling | Positive contact indication |
| Neutral protection setting | Without protection |
| Earth-leakage protection | Without |
| Height | 130 mm |
| Width | 75 mm |
| Depth | 60 mm |
| Environment | |
| Standards | JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25 ~ 70 °C |
| Ambient air temperature for storage | -35 ~ 85 °C |
SWAS Delivery Policy
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
Terms & Conditions
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.




















Reviews
There are no reviews yet.