BW32AAG – Fixed MCCB, 3 Pole, 3 Amps, 1.5kA/415 VAC

₨ 42,000.00

MOULDED CASE CIRCUIT BREAKERS  (MCCB)
WITH FIXED THERMAL &  MAGNETIC TRIPS

CurrentAC
Pole3P
Rated Current3 Amps
Breaking Capacity1.5 kA
ModelBW32 AAG

Optional accessories

Accessories 01 Accessories 01 + ₨1,000.00
10 People watching this product now!
Categories: ,
Description
Fuji Electric G-TWIN BW32AAG-3P003 3A MCCB

Series      :      G-TWIN BW Series
Model      :      BW32-AAG

G‑TWIN BW32-AAG is a 3-pole, fixed molded-case circuit breaker (MCCB) designed for general low-voltage line protection in industrial control panels and distribution installations. It has a 32AF frame and a 3A fixed hydraulic-magnetic trip unit, providing overload and instantaneous short-circuit protection. Its rated operational voltage is 440 VAC, and its breaking capacity is Icu/Ics 1.5/1 kA at 415 VAC (also 400/440 VAC). At 230/240 VAC, Icu/Ics is 2.5/2 kA. The breaker has a rated insulation voltage of 500 VAC and an impulse-withstand voltage of 6 kV. The 3-pole version measures 75 mm × 100 mm × 60 mm (W × H × D).  It conforms to IEC 60947-2, EN 60947-2 (CE), JIS C 8201-2-1, and GB 14048.2 (CCC).

MOULDED CASE CIRCUIT BREAKERS  (MCCB)
WITH FIXED THERMAL &  MAGNETIC TRIPS

Specification
Poles 3P   Not complete
Network type DC
AC
Network frequency 50/60 Hz
[In] rated current 100 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Mechanical durability 13000 cycles
Electrical durability 5000 cycles
Breaking capacity 25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2
2.5 kA at 250 V DC conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 100 A at 50 °C
Protection type Short-circuit protection
Overload protection
Pollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Local signalling Positive contact indication
Neutral protection setting Without protection
Earth-leakage protection Without
Height 130 mm
Width 75 mm
Depth 60 mm
Environment
Standards JIS C8201-2-2
EN/IEC 60947-2
GB/T 14048.2
EN/IEC 60947-1
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25 ~ 70 °C
Ambient air temperature for storage -35 ~ 85 °C

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “BW32AAG – Fixed MCCB, 3 Pole, 3 Amps, 1.5kA/415 VAC”

Your email address will not be published. Required fields are marked *

Downloads

   Data Sheet

   Catalog

   Cad Data

Shipping and Delivery

SWAS Delivery Policy

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

Terms & Conditions

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.